4.6 Introduction to Titration
A titration finds an unknown concentration by adding a solution of known concentration until the reaction is exactly complete. The calculation is stoichiometry with volumes.
How a titration works
In a titration, a measured volume of the unknown solution, the analyte, is placed in a flask. A solution of known concentration, the titrant, is added slowly from a buret, a long tube with a tap that reads the volume delivered. The titrant reacts with the analyte in a known ratio. The titration is stopped at the equivalence point, the point at which the moles of titrant added are exactly the amount needed to react with all the analyte, in the ratio shown by the balanced equation.
The equivalence point cannot be seen directly, so an indicator is added. This is a dye that changes color at a pH near the equivalence point. The point at which the color changes is the endpoint, and a well-chosen indicator makes it very close to the equivalence point. Phenolphthalein, which turns from colorless to pink, is common for strong base titrations.
Titrations are accurate because volumes can be measured to 0.01 mL. They are used to find the acidity of wine, the vitamin C in a juice and the concentration of a cleaning solution.
The calculation
The calculation follows stoichiometry. Say 25.00 mL of HCl is titrated with 0.100 M NaOH, and 20.00 mL is needed. The balanced equation is HCl + NaOH → NaCl + H2O, a 1 to 1 ratio. Moles of NaOH = 0.100 × 0.02000 = 2.00 × 10^-3 mol. Moles of HCl = 2.00 × 10^-3 mol. Molarity of HCl = 2.00 × 10^-3 ÷ 0.02500 = 0.0800 M.
If the ratio is not 1 to 1, use the coefficients. For H2SO4 + 2 NaOH → Na2SO4 + 2 H2O, each mole of H2SO4 needs 2 mol of NaOH. So 15.00 mL of 0.100 M NaOH, which is 1.50 × 10^-3 mol, reacts with 7.50 × 10^-4 mol of H2SO4. In 25.00 mL of acid, the concentration is 0.0300 M.
Use the volume of titrant actually added, which is the final reading minus the starting reading on the buret. Convert mL to L before multiplying by molarity.
Good technique and errors
Rinse the buret with the titrant, and rinse the pipet with the analyte, so that dilution does not change the concentrations. It is fine if the flask is wet with water, because water adds no moles of analyte. Remove air bubbles from the buret tip. Swirl while adding, and slow to single drops near the endpoint. Repeat until results agree within about 0.10 mL, then average the concordant trials.
Errors have predictable effects. If you overshoot the endpoint, you add more titrant than needed, so the calculated concentration of the analyte is too high. If an air bubble in the tip leaves during the titration, the reading shows more volume than was really delivered, so the result is also too high. If the buret is rinsed with water and not titrant, the titrant is diluted and more is needed, which also gives a result that is too high.
- Titrant: known concentration, in the buret.
- Analyte: unknown concentration, in the flask.
- Equivalence point: moles match the equation's ratio.
- Endpoint: the indicator changes color.
- Overshooting: gives an analyte concentration that is too high.
Redox and other titrations
Titrations are not limited to acids and bases. In a redox titration, the titrant is an oxidizing or reducing agent. Potassium permanganate is a popular titrant because it is purple and its product, Mn2+, is nearly colorless, so it acts as its own indicator. The first drop of excess permanganate gives a faint pink color that lasts, which marks the endpoint.
In a precipitation titration, a precipitate forms as titrant is added, and the endpoint is the point where precipitation ends. The calculation is the same each time: moles of titrant, mole ratio, then moles and concentration of the analyte.
Why it matters for the exam
Questions give titration data and ask for a concentration, a percent purity or the effect of an error. Show the moles of titrant, the ratio and the final division.
This topic builds on stoichiometry in 4.5. It leads to acid-base reactions in 4.8 and to titration curves in 8.5.
Key takeaways
- The titrant is added until the equivalence point.
- The endpoint is the indicator color change.
- Moles of titrant times the ratio gives moles of analyte.
- Convert mL to L.
- Use the buret reading difference.
- Overshooting gives a result that is too high.
- A wet flask does not affect the result.
- Permanganate is self-indicating.
How this shows up on the exam
- Multiple choice: calculate a concentration from titration data.
- Short answer: explain the effect of an air bubble.
- Long free response: analyze several trials and average them.
- Reasoning skill: justify the choice of indicator.
Common mistakes
- Using the initial buret reading as the volume.
- Forgetting the mole ratio when it is not 1 to 1.
- Saying a wet flask changes the result.
- Mixing up the endpoint and the equivalence point.
Key terms
- titration
- titrant
- analyte
- buret
- equivalence point
- endpoint
- indicator
- phenolphthalein
- mole ratio
- redox titration
- permanganate
- concordant trials
Check yourself
Topic 4.6 quiz
A 25.00 mL sample of HCl needs 20.00 mL of 0.100 M NaOH. What is the HCl concentration?