3.13 Beer-Lambert Law
The more concentrated a colored solution is, the more light it absorbs. The Beer-Lambert law turns that into a straight-line relationship you can use to find an unknown concentration.
Absorbance and transmittance
A spectrophotometer shines light of a chosen wavelength through a sample and measures how much gets through. The transmittance (T) is the fraction of light that passes through. The absorbance (A) is a logarithmic measure of how much light is absorbed: A = -log T. An absorbance of 0 means all light passes, an absorbance of 1 means 10% passes, and an absorbance of 2 means 1% passes.
A colored solution absorbs certain wavelengths and transmits others. Chemists choose the wavelength at which the substance absorbs most strongly, because the signal is largest there, and they use that same wavelength for every measurement in an experiment. The sample is placed in a small clear container called a cuvette, and a blank filled with pure solvent is used to set zero absorbance.
The method is useful for any substance that absorbs light, such as the copper(II) ion, which is blue, or permanganate, which is purple, and for many compounds in biology.
The Beer-Lambert law
The Beer-Lambert law states A = εbc. Here A is the absorbance, ε is the molar absorptivity, which is a constant for a given substance and wavelength, b is the path length, the width of the cuvette (usually 1.00 cm), and c is the concentration in mol/L. The relationship is linear: if the concentration doubles, the absorbance doubles, as long as the path length is the same.
A graph of absorbance against concentration for a series of known solutions is a straight line through the origin, called a calibration curve. Its slope is εb. To find an unknown concentration, measure its absorbance and read the matching concentration from the line, or use the equation. If a standard of 0.200 M has A = 0.40, then a solution with A = 0.30 has a concentration of 0.30 ÷ 0.40 × 0.200 = 0.150 M.
The law works best for dilute solutions. At high concentrations the particles interact, and the line curves. If an absorbance is too high, dilute the sample and account for the dilution factor in the final answer.
Doing the experiment well
Several habits improve accuracy. Wipe the cuvette so there are no fingerprints. Use the same cuvette and wavelength for all samples. Zero the instrument with a blank first. Make sure the solutions are mixed and free of bubbles. Prepare standards that bracket the expected concentration of the unknown, so you interpolate rather than extrapolate.
Errors give predictable results. A dirty cuvette adds to the absorbance, so the unknown would seem more concentrated than it is. A wavelength far from the peak lowers the sensitivity. An unmixed dilution makes the standards inaccurate and the line scattered.
- A = εbc: absorbance is proportional to concentration.
- Same cuvette and wavelength: keeps ε and b constant.
- Blank: sets zero absorbance.
- Calibration curve: straight line through the origin.
- Interpolate: use standards on both sides of the unknown.
Reading graphs and spectra
An absorption spectrum plots absorbance against wavelength. The peak is the wavelength of maximum absorbance. If a substance absorbs strongly near 600 nm, which is orange, the solution looks blue, the complementary color.
On the calibration graph, the slope gives εb. If the slope is 2.0 L/mol and b is 1.00 cm, then ε = 2.0 L/(mol·cm). Compare solutions on the same graph by their heights: a taller point at the same wavelength means a higher concentration.
Why it matters for the exam
Questions give absorbance data and ask for a concentration, a graph, or the effect of an experimental error. State the proportionality, use the same path length, and check the units.
This topic closes Unit 3. It uses molarity from 3.7 and light from 3.11, and it reappears in kinetics in Unit 5, where absorbance tracks how a reaction proceeds.
Key takeaways
- Absorbance A = -log T.
- A = εbc, so A is proportional to concentration.
- Path length is usually 1.00 cm.
- A calibration curve is a straight line through the origin.
- Use the wavelength of maximum absorbance.
- Zero the instrument with a blank.
- Dilute samples that are too concentrated.
- A dirty cuvette raises the absorbance.
How this shows up on the exam
- Multiple choice: predict absorbance after a dilution.
- Short answer: find an unknown concentration from a calibration curve.
- Long free response: analyze absorbance data from standards.
- Reasoning skill: justify an error's effect on the result.
Common mistakes
- Saying absorbance and transmittance both rise with concentration.
- Using different cuvettes for different samples.
- Forgetting the dilution factor.
- Using a nonzero blank.
Key terms
- spectrophotometer
- absorbance
- transmittance
- Beer-Lambert law
- molar absorptivity
- path length
- cuvette
- calibration curve
- blank
- concentration
- absorption spectrum
- dilution factor
Check yourself
Topic 3.13 quiz
A solution has absorbance 0.40. It is diluted to half its concentration. What is the new absorbance?