3.9 Separation of Solutions and Mixtures: Chromatography
Mixtures are separated by physical methods that use differences in properties. Chromatography uses differences in attraction to a stationary and a mobile phase, and distillation uses differences in boiling point.
Separating by physical properties
The parts of a mixture are not chemically bonded, so they can be separated by physical methods. Each method uses a difference in a property. Filtration separates an insoluble solid from a liquid, because the solid is too big to pass through the paper. Evaporation removes a liquid to leave a dissolved solid behind. Magnetism pulls out iron from a mixture. Decanting pours off a liquid from a settled solid.
To choose a method, ask what is different about the parts. A mixture of sand and salt water can be filtered to remove the sand, and the water can then be evaporated to recover the salt. In each case the substances stay chemically the same, and only their positions change.
Separating the parts of a compound is different. It needs a chemical change, such as electrolysis of water into hydrogen and oxygen.
Distillation
Distillation separates liquids in a solution by their boiling points. The mixture is heated, and the liquid with the lower boiling point vaporizes first. The vapor passes into a cooled tube called a condenser, where it turns back into a liquid and is collected. The liquid with the higher boiling point stays behind in the flask.
Distillation works because of differences in IMFs. In a mixture of ethanol and water, ethanol boils at about 78 °C and water at 100 °C, so ethanol vaporizes first. The first liquid collected is rich in ethanol, though it is not completely pure, because some water vapor comes with it. Repeating the process, or using a tall column, improves the separation.
Distillation is also used to get fresh water from seawater, since the dissolved salts do not vaporize and are left in the flask.
Paper and thin-layer chromatography
Chromatography separates the parts of a mixture by how strongly each is attracted to two phases. The stationary phase is a solid that stays in place, such as paper or a thin layer of silica on a plate. The mobile phase is the liquid solvent that moves through the stationary phase, carrying the mixture with it. A part that is attracted more strongly to the mobile phase travels farther. A part that is attracted more strongly to the stationary phase travels less.
In paper chromatography, a small spot of the mixture is placed near the bottom of a strip, and the strip is placed in a solvent so that the liquid creeps up the paper by capillary action. Each component moves at its own rate, and the colors separate into spots. The result is compared using the retention factor: Rf = distance traveled by the spot ÷ distance traveled by the solvent. Rf is always between 0 and 1 and is constant for a substance under the same conditions, so it can identify an unknown.
Polarity is the key. If the paper is polar and the solvent is nonpolar, polar compounds stick to the paper and move a short distance, while nonpolar compounds dissolve in the solvent and move far. The opposite happens when the stationary phase is nonpolar and the mobile phase is polar.
Column chromatography and reading results
In column chromatography, the stationary phase is packed in a glass tube and the solvent flows down through it. Components come out at different times, and they can be collected separately. In gas chromatography, the mobile phase is a gas, and the time each substance takes to reach the detector, its retention time, helps to identify it. Compounds with stronger attractions to the stationary phase come out later.
Suppose a spot travels 3.0 cm while the solvent travels 6.0 cm. The Rf is 3.0 ÷ 6.0 = 0.50. A second compound with Rf = 0.80 is more attracted to the mobile phase and less to the stationary phase. If the stationary phase is polar, the compound with the higher Rf is likely less polar.
- Filtration: separates an insoluble solid from a liquid.
- Distillation: uses boiling points.
- Chromatography: uses attraction to the stationary and mobile phases.
- Rf: spot distance over solvent distance.
- Higher Rf: more attracted to the mobile phase.
Why it matters for the exam
Questions give a chromatogram or describe a separation and ask you to explain it. Always compare the attractions of each component to each phase, and say which moves farther and why.
This topic builds on IMFs from 3.1 and solutions from 3.7. It leads to the spectroscopy ideas in 3.11, which are other tools for analyzing mixtures.
Key takeaways
- Mixtures are separated by physical methods.
- Filtration uses particle size.
- Distillation uses boiling points.
- Chromatography uses attraction to the stationary and mobile phases.
- Rf equals spot distance over solvent distance.
- Rf is between 0 and 1.
- Matching polarity to the mobile phase sends a compound farther.
- Separating a compound needs a chemical change.
How this shows up on the exam
- Multiple choice: pick a separation method.
- Short answer: calculate an Rf value.
- Long free response: explain the separation of two dyes.
- Reasoning skill: justify an order of travel using polarity.
Common mistakes
- Thinking chromatography separates by mass.
- Calculating Rf with the wrong distance, such as to the bottom of the spot.
- Saying a stronger attraction to the stationary phase means moving farther.
- Saying distillation breaks compounds apart.
Key terms
- filtration
- evaporation
- distillation
- chromatography
- stationary phase
- mobile phase
- retention factor
- Rf
- capillary action
- polarity
- condenser
- retention time
Check yourself
Topic 3.9 quiz
In paper chromatography with a polar paper and a nonpolar solvent, which compound travels farthest?